(3.16.218.216)
Users online: 4797     
Ijournet
Email id
 

International Journal of Physiology
Year : 2019, Volume : 7, Issue : 4
First page : ( 89) Last page : ( 93)
Print ISSN : 2320-6039. Online ISSN : 2320-608X.
Article DOI : 10.5958/2320-608X.2019.00146.X

A Comparative Study of Pulmonary Function Test in School Children of Industrial Area and Non Industrial Area

Kashyap Keshav1, Latiyar Anil2,*

1Associate professor, Department of Physiology, Chhattisgarh institute of medical sciences, Bhilaspur (CG)

2Assistant Professor, Department of Physiology, College name: LTBRKM Gov. Medical College, Jagdalpur

*Corresponding Author: Dr Anil Latiyar, Assistant Professor, Department of Physiology, College name: LTBRKM Gov. Medical College, Jagdalpur., Dimrapal, Type 4 quarter no: 21, jagdalpur, 494001, e-mail: dranillatiyar@gmail.com

Online published on 21 November, 2019.

Abstract

Background

Pulmonary function test is an important tool in the diagnosis, assessment and management of respiratory diseases in adults and older children. The main objective was to study the pulmonary function test in school children of industrial and Non industrial area.

Method

The study was carried out in a school of industrial area i.e., Advani Arlicon Higher secondary School, Urla Road, Birgaon and a school of Non Industrial area i.e., Vivekananda Higher Secondary School, Mana Camp of Raipur city from April to August 2012.. The subjects were evaluated through pulmonary function test by using Spirometry method. A total of 400 subjects aged between 11–18 years were included. For the study Permission from Institutional Ethics Committee was obtained. Initially informed individual consent was taken from all the patients included in the study.

Results

When Mean FEV1 (in liters) for Males in Cases was compared with Controls, p value was found to be <0.0001. When Mean FEV1 (in liters) for Females in Cases was compared with Controls, p value was found <0.0001. When PEFR (in liters/Sec) for Males in Cases was compared with Controls, p value was found to be 0.0290. When PEFR (in liters/Sec) for Females in Cases was compared with Controls, p value was found to be 0.3117.

Conclusion

To conclude, the problems are diverse, but it is important to keep close control over pollutants. Some preventable strategies need to be taken for acceptable environment for the future generations.

Top

Keywords

Pulmonary function test, School children's, Industrial area, Non industrial area.

Top

 
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
823,994,462 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.