(18.119.137.2)
Users online: 16492     
Ijournet
Email id
 

Research Journal of Pharmacy and Technology
Year : 2023, Volume : 16, Issue : 2
First page : ( 635) Last page : ( 639)
Print ISSN : 0974-3618. Online ISSN : 0974-360X.
Article DOI : 10.52711/0974-360X.2023.00108

Simultaneous gas chromatographic analysis of isopropyl alcohol, t-butanol, 2-bromo propane, toluene and acetic acid in teneligliptin drug

Rapeti Durgababu1,*, Narayanarao Kapavarapu Maruthi Venkata1, Shyamala Pulipaka2, Krishna Rallabhandi Murali3

1GVK Biosciences Pvt Ltd, Hyderabad, Telangana, India - 500076

2Physical Chemistry Department, Andhra University, Visakhapatnam, Andhra Pradesh, India - 530003

3Department of Physical and Nuclear Chemistry, and Department of Chemical Oceanography, Andhra University, Visakhapatnam, Andhra Pradesh, India - 530003

*Corresponding Author E-mail: durgababu_chem416@yahoo.com

Online Published on 11 October, 2023.

Abstract

Teneligliptin (TNN), a true third-generation gliptin, has firmly established itself as an essential therapeutic molecule in the therapy of diabetes. The monitoring of isopropyl alcohol (ISO), t-butanol (BUT), 2-bromo propane (BRO), toluene (TOU) and acetic acid (ACE) in TNN is necessary to maintain TNN’s stability, bioavailability and solubility. We have established a “gas chromatography” approach for ISO, BUT, BRO, TOU and ACE determination in TNN sample. The analysis of ISO, BUT, BRO, TOU and ACE in TNN were performed deploying ZB-624 analysing column. The flame ionizing sensor was deployed. Linear response was ascertained for ISO, BUT, BRO, TOU and ACE over the concentration arrays 29.96 to 7512ppm, 25.83 to 759 ppm, 48.48 to 762ppm, 4.92 to 1362ppm and 222.41 to 7527ppm, respectively. Detection limits were 8.99ppm (ISO), 7.75ppm (BUT), 14.55ppm (BRO), 1.34ppm (TOU) and 67.47ppm (ACE). The “gas chromatography” approach validation set their precision, specificity, accuracy and robustness. Routine monitoring and proper analysis of ISO, BUT, BRO, TOU and ACE in TNN sample in quality management laboratories could be accomplished deploying “gas chromatography” approach.

Top

Keywords

Simultaneous Gas Chromatographic Analysis.

Top

  
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
761,579,126 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.