(3.133.92.6)
Users online: 15329     
Ijournet
Email id
 

Year : 2013, Volume : 38, Issue : 1to4
First page : ( 110) Last page : ( 115)
Print ISSN : 0379-0479. Online ISSN : 2349-2120. Published online : 2013  3.

Operation and control strategies in pre-series testing of cold circulating pumps for ITER

Bhattacharya R.1, Vaghela H.1, Sarkar B.1, Srinivas M.1, Choukekar K.1

1ITER-India, Institute for Plasma Research, Near Indira Bridge, Bhat, Gandhinagar-382428, India,

Abstract

Cryo-distribution system of ITER is responsible for the distribution and control of forced- flow supercritical helium for cooling of the superconducting magnets and the cryo-pumps. The requirements of cold circulating pumps (CCP) for mass flow rates and performance are much higher than presently existing and commercially available one used at 4.0 K helium. Design up-scaling with pre-series test of CCP has been proposed including test infrastructure. Operation and control strategies for the test distribution box (TDB) of test infrastructure have been developed and analyzed using steady state and dynamic process simulation to cope with the functional requirements of CCPs. Off-normal scenario with CCP inlet pressure variation is an important concern, dynamic process responses during such scenario have been evaluated to verify the operability of CCP. The paper describes process simulation to cope with the functional requirements of CCPs along with evaluation of off-normai scenario to verify the operability of CCP.

Top

Keywords

Cold circulator supercritical helium.

Top

  
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
751,525,403 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.