(3.143.25.144)
Users online: 17477     
Ijournet
Email id
 

Research Journal of Pharmacy and Technology
Year : 2022, Volume : 15, Issue : 5
First page : ( 2103) Last page : ( 2109)
Print ISSN : 0974-3618. Online ISSN : 0974-360X.
Article DOI : 10.52711/0974-360X.2022.00349

Development and validation of a new stability indicating RP-HPLC method for the quantification of Budesonide in pharmaceutical dosage forms in presence of an internal standard

Bandaru Sai Pavan Kumar, Annapurna Mukthinuthalapati Mathrusri*

Department of Pharmaceutical Analysis, GITAM Institute of Pharmacy, Gandhi Institute of Technology and Management (Deemed to be University), Visakhapatnam, Andhra Pradesh-530045, India

*Corresponding Author E-mail: mmukthin@gitam.edu

Online published on 20 February, 2023.

Abstract

Budesonide is a glucocortico steroid used for the treatment of nasal polyposis, asthma and Crohn’s disease. A stability indicating RP-HPLC method has been developed and validated for the quantification of Budesonide in pharmaceutical dosage forms in presence of an internal standard, Etoricoxib. Mobile phase including a mixture of formic acid: acetonitrile: methanol (25: 10: 65) was chosen for the chromatographic study with flow rate 1.0 ml/min. The PDA detection was carried at 240 nm and the elution was achieved on isocratic mode using Zorbox C18 column. Beer-Lambert’s law was obeyed over a concentration range 0.05-120 μg/ml and the linear regression equation was y = 0.0489x + 0.003 with correlation coefficient 0.9997). The LOQ and LOD was found to be and 0.0393 and 0.1192 μg/ml. Stress degradation studies such as acidic hydrolysis, alkaline hydrolysis, oxidation and thermal degradation were performed. The method was validated for the parameters linearity, precision, accuracy, robustness as per ICH guidelines and the proposed stability indicating liquid chromatographic method was found to be simple, accurate, precise and robust and can be applied for the assay Budesonide formulations.

Top

Keywords

RP-HPLC, Budesonide, Validation.

Top

  
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
751,167,789 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.