(3.144.96.159)
Users online: 9858     
Ijournet
Email id
 

Baba Farid University Dental Journal
Year : 2014, Volume : 5, Issue : 3
First page : ( 97) Last page : ( 107)
Print ISSN : 0976-8181. Online ISSN : 2230-7273.

A Comparative Evaluation of Bond Strength and Interfacial Microleakage of Different Bonding Agents − An In-Vitro Study

Markan Sheenam1, Pasricha Shinam2,*, Dhawan Rajan3, Makkar Sameer4

1Post Graduate Student, H. No. 384, Sec. 21, Panchkula

2Senior Lecturer, H. No. 384, Sec. 21, Panchkula

3Professor, H. No. 384, Sec. 21, Panchkula

4Professor, H. No. 384, Sec. 21, Panchkula

*Address for Correspondence: -Dr. Shinam Pasricha, Senior Lecturer, H. No. 384, Sec. 21, Panchkula

Online published on 18 May, 2016.

Abstract

Aim

This study was conducted to evaluate and compare the microtensile bond strength and interfacial microleakage of different bonding agents commercially available.

Materials and Method

For microleakage evaluation, Class V cavities (4x3x2) were prepared on 60 human premolars. The samples were divided into four groups-(Group A: Tetric N Bond total etch adhesive, Group B: Clearfil SE Bond, Group C: Tetric N Bond self etch adhesive, Group D: Adper Easy Bond) and restored with composite material. All specimens were then immersed in methylene blue dye and sectioned. Dye penetration at the occlusal and gingival margin was examined using a stereomicroscope at 20x. For microtensile bond strength, 60 specimens of a standardized size (1.5x1.5x2.5 mm) were prepared from each tooth. The enamel surface was grounded and flatened. Teeth were divided into 4 groups according to bonding agent used and sectioned, decalcified and deproteinated. These specimens were mounted on stubs and evaluated under scanning electron microscope.

Statisticalanalysis

Statistical analysis was done using one way Anova test and Post-Hoc test.

Results

Tetric N bond self etch showed maximum leakage and Clearfil SE Bond two-step self-etch adhesive revealed higher bond strength.

Conclusion-Total etch bonding agent exhibited less interfacial microleakage than self etch bonding agents but higher bond strength was noted with two step self-etch adhesive.

Top

Keywords

microleakage, microtensile bond strength, total-etch adhesive, self-etch adhesive.