(52.14.85.76)
Users online: 6144     
Ijournet
Email id
 

Indian Journal of Public Health Research & Development
Year : 2019, Volume : 10, Issue : 12
First page : ( 2118) Last page : ( 2122)
Print ISSN : 0976-0245. Online ISSN : 0976-5506.
Article DOI : 10.37506/v10/i12/2019/ijphrd/192310

Evaluation of Intensity of LED Curing Light on the Depth of Cure of Composite-An in Vitro Study

Lakshmisree A G1,*, Karthick Arumugam2, Geethapriya Nagarajan3, Subbiya Arunajatesan4

1Third Year PG Student, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College And Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India

2Professor, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College And Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India

3Reader, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College And Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India

4Professor & Head, Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College And Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai, Tamilnadu, India

*Corresponding Author: Lakshmisree A G, M.D.S., Third Year PG Student Department of Conservative Dentistry and Endodontics, Sree Balaji Dental College and Hospital, Bharath Institute of Higher Education and Research, Narayanapuram, Pallikaranai, Chennai-600100, Tamilnadu, India, Phone: 8754132036, Email: sree4chinnu@gmail.com

Online published on 4 April, 2020.

Abstract

Aim

To evaluate the effect of intensity of curing light on depth of cure of resin based composite material and also to bring about the awareness to the dentists community regarding the maintenance of intensity of curing light unit.

Materials and Method

The resin based composite material of A2 shade was tightly packed into a plastic mould (fig1D) of diameter 6mm and depth 5mm. The sample size for each group was 10 in numbers, which was irradiated from the top, for each varying intensity, with light tip in nearest contact. An LED Light Curing unit was used throughout this study; the input voltage to the curing light was controlled by a regulated dc power supply. Four different settings of voltage 2.9V, 3.0V, 3.1V and 3.2V which yielded the light intensity as 200mW/cm2, 250mW/cm2, 300 mW/cm2 and 375 mW/cm2, the power supply to the curing light then was set to this voltage level i.e. 5V and the intensity was verified according to the ISO test method to determine the depth of cure of the resin-based composites.

Results

Statistical difference between the groups and among the groups were calculated using Students ‘t ’test. Results clearly shows a statistically significant difference in depth of cure with varying intensity of light used.

Conclusion

Depth of cure is comparatively low when intensity of curing light is low. These measurements provide valuable baseline information about the specific depth of cure for different intensities of curing light on resin-based composite materials used by dentists.

Top

Keywords

Intensity of light, depth of cure, composite.

Top

 
║ Site map ║ Privacy Policy ║ Copyright ║ Terms & Conditions ║ Page Rank Tool
746,015,298 visitor(s) since 30th May, 2005.
All rights reserved. Site designed and maintained by DIVA ENTERPRISES PVT. LTD..
Note: Please use Internet Explorer (6.0 or above). Some functionalities may not work in other browsers.